Tester, Utp Stp

  • Ideal
  • LinkMaster(TM) Tester, CAT Safety Rating Not Applicable, Testing Functions Wire Mapping, Adapters Included RJ45, Connector Type RJ45, Maximum Speed Measured Not Applicable, Data Safe Monitor No, Display Screen Type LCD, Includes Main Test Unit, Remote, Maximum Cable Length Not Applicable, Fault Location Pulse Duration Not Applicable, Wire Mapping Detections Opens, Reversed Pairs, Shorts, Split Pairs, Alert Type Light, Port Number Display Yes, Number of Results Stored Not Applicable

    graingerSKU: 5LJ29, mscSKU: 05023296, zoro_no: G1735334, mongo_id: 65bbe81a9a749db82277530c

Web Price
$110.10 / each
Qty

Product Details

RJ45
RJ45
Light
Checks for shorts, miswires, reversals, and split pairs
Network
LR44
AA
No
Twisted Pair
No
No
Not Included
Not Applicable
CAT3, CAT5, CAT5e, CAT6, CAT6A, Twisted Pair
RJ45
Yes
China
No
No
No
No
1.3
Split Pair Testing, Short Circuit Testing, Open Circuit Testing
LED
LCD
No
Yes
No
No
Yes
Not Applicable
3.3
No
Main Test Unit, Remote
Yes
None
Not Applicable
Not Applicable
Not Applicable
600 ft
Not Applicable
3 ft
Yes
4
2
Not Applicable
Yes
Not Applicable
1
No
No
Yes
Copper Cable Wire Mapping
LinkMaster PRO
LinkMaster PRO Tester
Cable Network Tester
No
Battery low LED, OPEN - There is no OPEN LED indication. A typical cable may have 2, 3, or 4 pairs. OPENS are displayed as an unlit LED. The user will determine if a pair is present and continuous or OPEN by comparing the illuminated LEDs to the expected number of pairs that should be good. For example, when testing a 4 pair cable, three illuminated LEDs in the PASS area indicate the presence of an OPEN condition in one of the pairs, SHORT - A short circuit condition exists, MISWIRE - Indicates the improper assignment of individual wire pairs to pins for the wiring schemes tested. Tester checks T568A, T568B, 10Base-T, and Token Ring configurations, REVERSAL - Reverse wiring means the pin for one wire in a pair is connected to the opposite pin for the pair in the remote jack, SPLITPAIRS - Split Pairs occur when the tip (positive conductor) and ring (negative conductor) of two twisted pairs are interchanged; Pass Indicators: T568A and T568B, Four green LEDs on pairs 1-2, 3-6, 4-5, and 7-8. All four pairs are terminated correctlyToken Ring, Two green LEDs on pairs 3-6, and 4-5. Both pairs terminated correctly10 Base-T, Two green LEDs on pairs 1-2, and 3-6. Both pairs terminated correctlyShield, Green SHIELD LED indicates the shield on the cable is correctly and continuously wired through the modular plug termination; FAIL Indicators: A flashing pair LED indicates that this wire pair has a fault. A flashing LED in the FAIL section will indicate which fault was detected. Multiple flashing LEDs indicate multiple pairs and/or multiple faults. Best practice is to correct cable faults until cable is verified as correct with appropriate green LEDs
No
Wiremap
Wire Mapping
No
No
No
2
No
Opens, Reversed Pairs, Shorts, Split Pairs
No